Fujitsu-siemens-computers SPARC Enterprise M8000 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Počítače Fujitsu-siemens-computers SPARC Enterprise M8000. Fujitsu Siemens Computers SPARC Enterprise M8000 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 162
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - SPARC Enterprise

Dynamic Reconfiguration (DR) User’s GuideSPARC Enterprise M4000 / M5000 / M8000 / M9000 Servers English

Strany 2

viii SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.5 Examples: Replacing a System Board 4–124.5.1 Example: Rep

Strany 3 - (DR) User's Guide

4-10 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.4 Example: Moving a System BoardThis section provides an ex

Strany 4

Chapter 4 Practical Examples of DR 4-113. Check the status of the move-destination domain.Execute the showdcl(8) command to display domain information

Strany 5

4-12 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20077. Check the status of the move-destination domain and moved

Strany 6

Chapter 4 Practical Examples of DR 4-134.5.1 Example: Replacing a Uni-XSB System BoardFIGURE 4-8 Example: Replacing a Uni-XSB System Board1. Login to

Strany 7 - Contents

4-14 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074. Delete the system board.Execute the deleteboard(8) command

Strany 8

Chapter 4 Practical Examples of DR 4-158. Check the status of the domain.Execute the showdcl(8) command to display domain information, and thencheck t

Strany 9 - Contents vii

4-16 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.5.2 Example: Replacing a Quad-XSB System BoardFIGURE 4-9 Ex

Strany 10

Chapter 4 Practical Examples of DR 4-173. Check the status of all related system boards.Execute the showboards(8) command to display system board info

Strany 11

4-18 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20076. Check the status of all related system boards.Execute the

Strany 12

Chapter 4 Practical Examples of DR 4-199. Check the status of all related domains.Execute the showdcl(8) command to display domain information, and th

Strany 13

ixFiguresFIGURE 1-1 Uni-XSB and Quad-XSB (Midrange Servers) 1–2FIGURE 1-2 Uni-XSB and Quad-XSB (High-end Servers 1–3FIGURE 1-3 DR Processing Flow 1–5F

Strany 14 - DR-related Commands 3–26

4-20 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.6 Examples: Reserving DomainConfiguration ChangesThis secti

Strany 15 - Preface xiii

Chapter 4 Practical Examples of DR 4-212. Check the status of the system board to be added.Execute the showboards(8) command to display system board i

Strany 16 - Audience

4-22 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.6.2 Example: Reserving a System Board DeleteFIGURE 4-11 Exa

Strany 17 - Documentation

Chapter 4 Practical Examples of DR 4-235. Check the reserved status of the system board.Execute the showboards(8) command with the -v option specified

Strany 18 - Book Titles Order No

4-24 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20073. Check the status of the move-destination domain.Execute th

Strany 19 - Documents

Chapter 4 Practical Examples of DR 4-258. Check the status of the move-destination domain and moved system board.Execute the showdcl(8) command to che

Strany 20 - Text Conventions

4-26 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007

Strany 21 - Prompt Notations

A-1APPENDIXAMessage Meaning and HandlingThis appendix explains the meaning and handling of DR-related messages.A.1 Solaris OS MessagesThis section exp

Strany 22 - Your Comments

A-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007OS unconfigure dr@0:SBX::memory[Explanation] Unconfigure memor

Strany 23 - Reader's Comment Form

Appendix A Message Meaning and Handling A-3[Explanation] Suspending device driversDR: in-kernel unprobe board <board>[Explanation] Unprobing the

Strany 24 - BUSINESS REPLY MAIL

x SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007FIGURE 4-10 Example: Reserve a System Board Add 4–20FIGURE 4-11

Strany 25 - Reconfiguration

A-4 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Explanation] Internal error during kernel migration[Remedy] P

Strany 26 - Quad-XSB

Appendix A Message Meaning and Handling A-5[Remedy] Disable interrupt on cpu X with psradm -I and if this command failsagain, respond in the manner di

Strany 27

A-6 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Explanation] There may be inconsistency in the system.[Remedy

Strany 28 - Basic DR Terms

Appendix A Message Meaning and Handling A-7dr_pre_release_cpu: thread(s) bound to cpu X[Explanation] The thread in the process is bound to the detache

Strany 29 - 1.2 Basic DR Functions

A-8 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Remedy] Please repeat the action. If the problem remains, ple

Strany 30 - 1.2.3 Moving a System Board

Appendix A Message Meaning and Handling A-9Cannot stop user thread: <pid> <pid> ...[Explanation] The DR driver cannot stop all the user pr

Strany 31 - 1.3 Security

A-10 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Invalid argument[Explanation] Invalid argument is passed to t

Strany 32

Appendix A Message Meaning and Handling A-11[Explanation] There may be inconsistency in the system.[Remedy] Please contact customer service.[Output] C

Strany 33 - 2.1.1 System Board Components

A-12 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Explanation] DR fails to allocate enough memory to perform c

Strany 34

Appendix A Message Meaning and Handling A-13[Explanation] Detected lack of memory resource.[Remedy] Check the size of memory, detach the board and att

Strany 35

xiTablesTABLE 1-1 Basic DR Terms 1–3TABLE 1-2 Terms Related to Hardware Configurations 1–4TABLE 2-1 Unit of Degradation 2–14TABLE 2-2 Domain Status 2–

Strany 36 - 2.1.1.1 CPU

A-14 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Memory operation refused: dr@0:SBX::memory[Explanation] The D

Strany 37 - (1) Kernel Memory Board

Appendix A Message Meaning and Handling A-15[Remedy] Repeat the action. If this error message appears again, please contactcustomer service.[Output] C

Strany 38 - (1.2) Floating Boards

A-16 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Operation already in progress: dr@0:SBX::cpuY[Explanation] Th

Strany 39 - (1.4) Copy-rename

Appendix A Message Meaning and Handling A-17[Output] Console and Standard OutputCannot setup resource map opl-fcodemem[Explanation] Resource memory ma

Strany 40 - (2) User Memory Board

A-18 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Explanation] A claim request with a nonzero hint came from t

Strany 41 - (2) Deleting an I/O Device

Appendix A Message Meaning and Handling A-19[Explanation] The node was not destroyed.[Remedy] Please contact customer service.IKP: destroy chip (<b

Strany 42

A-20 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Remedy] Please contact customer service.I/O callback failed

Strany 43

Appendix A Message Meaning and Handling A-21[Remedy] Please contact customer service.Failed to remove CMP xx on board n[Explanation] Internal error du

Strany 44 - 2.2.1 Conditions Using XSCF

A-22 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Explanation] An unknown resource type was found in the resou

Strany 45 - 2.2.2 Settings Using XSCF

Appendix A Message Meaning and Handling A-23SCF error[Explanation] Internal error happened during kernel migration.[Remedy] Please contact customer se

Strany 46 - 2.2.2.2 Floating Board Option

xii SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007TABLE 3-15 Options of the moveboard Command 3–20TABLE 3-16 DR

Strany 47 - 2.2.2.4 Omit-I/O Option

A-24 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007XSB#XX-X is currently unavailable for DR. Try again later.[Ex

Strany 48

Appendix A Message Meaning and Handling A-25[Remedy] Find out the cause of the DR failure referring monitoring message anderrorlog. Confirm the patch

Strany 49 - 2.4.1 Domain Status

A-26 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007An internal error has occurred. Please contact your systemadm

Strany 50 - 2.4.2 System Board Status

Appendix A Message Meaning and Handling A-27[Explanation] The specified system board (XSB#XX-X) has already been executedby another operation.[Remedy]

Strany 51 - System Board Management Items

A-28 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Invalid parameter.[Explanation] There is an error in the spec

Strany 52 - 2.4.3 Flow of DR Processing

Appendix A Message Meaning and Handling A-29[Explanation] Confirming whether DR operation is going to be executed or not.Input "y" to execut

Strany 53

A-30 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Remedy] Power off the domain by specifying "-c reserve&

Strany 54

Appendix A Message Meaning and Handling A-31[Remedy] Find out the cause of the DR failure referring monitoring message andconsole message. Try again a

Strany 55

A-32 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007[Explanation] Confirming whether DR operation is going to be

Strany 56

Appendix A Message Meaning and Handling A-33Invalid parameter.[Explanation] There is an error in the specified argument or operand.[Remedy] Confirm th

Strany 57

Preface xiiiPrefaceThis manual describes the Dynamic Reconfiguration (DR hereafter) functionprovided by SPARC Enterprise servers.This manual is intend

Strany 58

A-34 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007The specified parameter is not supported in this model.[Expla

Strany 59 - 2.5.2 Swap Area

Appendix A Message Meaning and Handling A-35[Remedy] Confirm that the DSCP setting is correct, confirm that the dsc process isrunning fine on the doma

Strany 60 - 2.5.4 Memory Mirror Mode

A-36 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007

Strany 61 - 2.5.6 XSCF Failover

B-1APPENDIXBExample: Confirm Swap Space SizeThis example shows one way to analyze the physical memory on a system board todetermine whether the system

Strany 62

B-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Notice in the Memory section that 2048 MB (2GB) of physical me

Strany 63 - DR User Interface

Glossary-1GlossaryThis glossary describes some of the terms used in this manual.Capacity on Demand(COD) An option that provides additional CPU process

Strany 64 - DR Operation Commands

Glossary-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007eXtended SystemControl facility unit(XSCFU) The XSCF bo

Strany 65 - Display items Description

Glossary-3privileges Specific permissions granted to users. This system has platform administrator,platform operator, domain administrator, domain ope

Strany 66

Glossary-4 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007

Strany 67

Index-1IndexAAdd, 1-3addboard, 3-2, 3-15, 3-22addfru, 3-26addition, 1-6, 2-20, 2-27, 3-15, 4-2, 4-6Assign, 1-3BBasic DR Terms, 1-3CCapacity on Demand,

Strany 68

xiv SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007AudienceThis manual is intended for users, who administrate SP

Strany 69

Index-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007move, 1-6, 2-23, 3-19, 4-4, 4-10moveboard, 3-2, 3-19Oomit-I

Strany 71

Herausgegeben von / Published byFujitsu Siemens Computers GmbH*U41684-J-Z816-2-76 *U41684-J-Z816-2-76 Bestell-Nr./ Order No.:U41684-J-Z816-2-76

Strany 72

Preface xvGlossary and Index GlossaryThe glossary explains the terms used in this manual IndexThe index provides keywords and corresponding referenc

Strany 73

xvi SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Note – " x " in the order number is the version numb

Strany 74

Preface xviiContact the field engineer.The following files or document are provided.i. Firmware program file (XSCF Control Package (XCP) file)ii. XSCF

Strany 76

xviii SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007ModelsThe model names used in this manual are as follows.Tex

Strany 77 - 3.1.6 Adding a System Board

Preface xixPrompt NotationsThe prompt notations used in this manual are as follows.Syntax of the Command Line Interface(CLI)The command syntax is desc

Strany 78

xx SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007 The command syntax is shown in a frame such as this one.Examp

Strany 79 - 3.1.7 Deleting a System Board

Preface xxiReader's Comment Form

Strany 80

xxii SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007FOLD AND TAPEFOLD AND TAPEBUSINESS REPLY MAILFIRST-CLASS MAIL

Strany 81 - 3.1.8 Moving a System Board

1-1CHAPTER1Overview of DynamicReconfigurationThis chapter provides an overview of Dynamic Reconfiguration, which is controlledby the eXtended System C

Strany 82

1-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007into four boards is called a Quad-XSB. Each composition of phy

Strany 83

Chapter 1 Overview of Dynamic Reconfiguration 1-3FIGURE 1-2 Uni-XSB and Quad-XSB (High-end ServersTABLE 1-1 and TABLE 1-2 list DR-related terms.TABLE

Strany 84

1-4 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Unconfigure To unconfigure a system board in the Solaris OS.Re

Strany 85

Chapter 1 Overview of Dynamic Reconfiguration 1-51.2 Basic DR FunctionsThis section describes the basic DR functions.FIGURE 1-3 shows DR processing.FI

Strany 86

SPARC®EnterpriseM4000/M5000/M8000/M9000Servers Dynamic Reconfiguration(DR) User's GuideOrder No. U41684-J-Z816-2-76Part No.819-7898-11September 20

Strany 87 - 3.2 Command Reference

1-6 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007In the example shown in FIGURE 1-3, system board #2 is deleted

Strany 88 - DR-related Commands

Chapter 1 Overview of Dynamic Reconfiguration 1-71.2.4 Replacing a System BoardYou can use DR to remove a system board from a domain and either add it

Strany 89 - 3.4 RCM Script

1-8 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007For details of XSCF shell commands provided for DR, see Sectio

Strany 90

2-1CHAPTER2What You Must Know Before UsingDRThis chapter provides information you must know to successfully use the DRfunctions.2.1 System Configurati

Strany 91 - Practical Examples of DR

2-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007FIGURE 2-1 Example of Hardware Configuration (with Uni-XSB of

Strany 92

Chapter 2 What You Must Know Before Using DR 2-3FIGURE 2-2 Example of Hardware Configuration (with Quad-XSBs of Midrange Server)CMU IOUMemoryXSB 00-2M

Strany 93

2-4 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007FIGURE 2-3 Example of a Hardware Configuration (with Uni-XSBs

Strany 94 - - Operation status and

Chapter 2 What You Must Know Before Using DR 2-5A CPU to be deleted must meet the following conditions: No running process is bound to the CPU to be

Strany 95 - Addition reservation

2-6 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007 To control whether a system board contains kernel memory, us

Strany 96

Chapter 2 What You Must Know Before Using DR 2-7When the kernel cage is enabled, kernel memory is assigned to system boards in theorder of their addre

Strany 97

PleaseRecycleCopyright 2007 FUJITSU LIMITED, 1-1, Kamikodanaka 4-chome, Nakahara-ku, Kawasaki-shi, Kanagawa-ken 211-8588, Japan. All rightsreserved.Su

Strany 98

2-8 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Once the copy-destination board has been selected, the Solaris

Strany 99

Chapter 2 What You Must Know Before Using DR 2-9Deleting or moving a user memory board fails if either of the following statements istrue: The swap a

Strany 100 - 00 Running

2-10 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Note – Do not move a device that is part of a redundant confi

Strany 101

Chapter 2 What You Must Know Before Using DR 2-11Moreover, a system board that is pooled can be assigned to a domain only when it isregistered on DCL.

Strany 102

2-12 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007When kernel memory is copied, the Solaris OS is temporarily s

Strany 103

Chapter 2 What You Must Know Before Using DR 2-13operation.As a matter of course, system boards to be deleted, moved, or replaced have alreadybeen reg

Strany 104

2-14 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Note – Enable the configuration policy option when the power

Strany 105

Chapter 2 What You Must Know Before Using DR 2-152.2.2.3 Omit-memory OptionWhen the omit-memory option is enabled, the memory on a system board cannot

Strany 106

2-16 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Note – Enable the omit-I/O option when the system board is in

Strany 107

Chapter 2 What You Must Know Before Using DR 2-17If the kernel cage is disabled, the system may run more efficiently, but kernelmemory will be spread

Strany 108

Copyright 2007 FUJITSU LIMITED, 1-1, Kamikodanaka 4-chome, Nakahara-ku, Kawasaki-shi, Kanagawa-ken 211-8588, Japon. Tous droitsréservés.Entrée et revu

Strany 109

2-18 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007XSCF manages the following aspects of domain status:To perfor

Strany 110 - Configuration Changes

Chapter 2 What You Must Know Before Using DR 2-19The table below lists the status types available for individual management items.XSCF changes and con

Strany 111

2-20 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007To perform a DR operation for a system board, you must determ

Strany 112

Chapter 2 What You Must Know Before Using DR 2-21FIGURE 2-5 Flow of System Board Addition Processing2.4.3.2 Flowchart: Deleting a System BoardThe flow

Strany 113

2-22 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Each system board status indicated in FIGURE 2-6 is the main

Strany 114

Chapter 2 What You Must Know Before Using DR 2-232.4.3.3 Flowchart: Moving a System BoardThe flow of DR operations and the transition of system board

Strany 115

2-24 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007FIGURE 2-7 Flow of System Board Move ProcessingProcess to cha

Strany 116

Chapter 2 What You Must Know Before Using DR 2-252.4.3.4 Flowchart: Replacing System BoardThe flow of DR operations and the transition of system board

Strany 117 - A.1.1 Transition Messages

2-26 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007FIGURE 2-8 Flow of System Board Replacement ProcessingDeletio

Strany 118

Chapter 2 What You Must Know Before Using DR 2-272.5 Operation ManagementThis section describes the premises and the actions for DR operations.2.5.1 I

Strany 120 - A.1.3 Warning Messages

2-28 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007memory contents. Be aware that some of the total swap space m

Strany 121

Chapter 2 What You Must Know Before Using DR 2-29For example, when a kernel memory board with memory mirror mode enabled isdeleted or moved, kernel me

Strany 122

2-30 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20072.5.8 Deletion of Board with DVD DriveTo delete the system bo

Strany 123

3-1CHAPTER3DR User InterfaceThis chapter describes the user interfaces for DR.3.1 How To Use the DR User InterfaceXSCF provides two user interfaces fo

Strany 124

3-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007The sections below describe the DR display and DR operation co

Strany 125

Chapter 3 DR User Interface 3-3TABLE 3-3 Options of the showdcl CommandOption Description-a Displays configuration information and status of all domai

Strany 126

3-4 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007The table below lists the items displayed by the showdcl(8) co

Strany 127

Chapter 3 DR User Interface 3-53.1.2 Displaying Domain StatusThe showdomainstatus(8) command lists the domains in the system and theirstatus. This com

Strany 128

3-6 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007The following example shows a display of the showdomainstatus

Strany 129

Chapter 3 DR User Interface 3-7The following examples show the format and options of the showboards(8)command.The table below lists the items displaye

Strany 130

vContentsPreface xiii1. Overview of Dynamic Reconfiguration 1–11.1 DR 1–11.2 Basic DR Functions 1–51.2.1 Adding a System Board 1–61.2.2 Deleting a Sys

Strany 131

3-8 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Assignment Status of assignment to domain configurationUnavail

Strany 132

Chapter 3 DR User Interface 3-9The following examples show displays of the showboards(8) command Example 1: Display of information on all system boar

Strany 133

3-10 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007 Example 2: Display of detailed information on all system bo

Strany 134

Chapter 3 DR User Interface 3-11Note – The showdevices(8) command only reports information about a runningdomain.TABLE 3-9 Options of the showdevices

Strany 135

3-12 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007The following example shows a display by the showdevices(8) c

Strany 136

Chapter 3 DR User Interface 3-13 Example: Display of device information on XSB00-03.1.5 Displaying System Board ConfigurationInformationUse the showf

Strany 137

3-14 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007The table below lists the items displayed by the showfru(8) c

Strany 138

Chapter 3 DR User Interface 3-153.1.6 Adding a System BoardUse the addboard(8) command to add a system board to a domain or reserve theaddition of a s

Strany 139 - A.2.1 addboard

3-16 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Note – (Note 1) In the system board addition processing execu

Strany 140

Chapter 3 DR User Interface 3-17Note – (Note 3) If a system board has been forcibly added to a domain by theaddboard(8) command with the -f option spe

Strany 141

vi SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20072.1.4 Checklists for System Configuration 2–112.1.5 Reservation

Strany 142 - A.2.2 deleteboard

3-18 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007TABLE 3-14 Options of the deleteboard CommandOption Descripti

Strany 143

Chapter 3 DR User Interface 3-19Note – (Note 1) The time required for system board deletion processing depends onthe amount of hardware resources moun

Strany 144 - A.2.3 moveboard

3-20 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007The following examples show the format and options of the mov

Strany 145

Chapter 3 DR User Interface 3-21Note – (Note 1) The time required for system board deletion processing in themove-source domain depends on the amount

Strany 146

3-22 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007Note – (Note 2) If the DR processing executed by the moveboar

Strany 147

Chapter 3 DR User Interface 3-23Note – (Note 1) Before replacing a system board, you must know the division typeof the replacement-target PSB and the

Strany 148 - A.2.4 setdcl

3-24 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20073.1.10 Reserving a Domain Configuration ChangeUse the addboar

Strany 149 - A.2.5 setupfru

Chapter 3 DR User Interface 3-253.2 Command ReferenceThis section lists the DR commands and other commands related to DR.For details of the commands,

Strany 150 - A.2.6 showdevices

3-26 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007TABLE 3-18 DR-related CommandsCommand name Functionpoweron Tu

Strany 151

Chapter 3 DR User Interface 3-273.3 XSCF WebXSCF Web lets you execute DR functions from a browser. XSCF Web is beyond thescope of this document. For d

Strany 152

Contents vii2.5.6 XSCF Failover 2–292.5.7 Kernel Memory Board Deletion 2–292.5.8 Deletion of Board with DVD Drive 2–303. DR User Interface 3–13.1 How

Strany 153

3-28 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007

Strany 154

4-1CHAPTER4Practical Examples of DRThis chapter provides examples of DR operations, such as the addition, deletion,move, and replacement of system boa

Strany 155 - Glossary

4-2 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.1.1 Flow: Adding a System BoardFIGURE 4-1 Flow: Adding a Sys

Strany 156

Chapter 4 Practical Examples of DR 4-34.1.2 Flow: Deleting a System BoardFIGURE 4-2 Flow: Deleting a System BoardChecking operation andChecking the do

Strany 157

4-4 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.1.3 Flow: Moving a System BoardFIGURE 4-3 Flow: Moving a Sys

Strany 158

Chapter 4 Practical Examples of DR 4-54.1.4 Flow: Replacing a System BoardFIGURE 4-4 Flow: Replacing a System BoardDeletion reservationoperation for t

Strany 159

4-6 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.2 Example: Adding a System BoardThis section provides an exa

Strany 160

Chapter 4 Practical Examples of DR 4-7If you need to change the PSB configuration, use the setupfru(8) command. Ifthe system board to be added is not

Strany 161

4-8 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 20074.3 Example: Deleting a System BoardThis section provides an e

Strany 162 - *U41684-J-Z816-2-76 *

Chapter 4 Practical Examples of DR 4-93. Check the status of the system board to be deleted.Execute the showboards(8) command to display system board

Komentáře k této Příručce

Žádné komentáře